Explosion-Proof Hydrogen Pressure Transducer E2X & E2F

Ashcroft

  • Hydrogen Pressure Transducer uses Ashcroft’s proven CVD thin film technology
  • Rugged 316 stainless steel Housing
  • Highly configurable with a wide selection of pressure connections and electrical terminations
  • 4-20mA or multiple Voltage outputs available
  • E2X- Flameproof, intrinsically safe and non-incendive approval for explosion-proof/hazardous applications
  • E2F- Flameproof approval for explosion-proof/hazardous applications

Explosion-proof hydrogen pressure transducer E2X & E2F

  • The Ashcroft E2X and E2F pressure transducers fulfills a wide spectrum of pressure sensing requirements when explosion or flameproof hazardous approvals are required.
  • Using Ashcroft’s proven CVD thin film sensor technology provides a reliable and repeatable sensor manufactured to Ashcroft’s TruAccuracy terminal point standard.
  • The Ashcroft’s straight forward TruAccuracy standard eliminates confusion from statistically derived accuracy specifications and avoids the need for user calibration at the time of installation.
  • This makes the E2X and E2F ideal for demanding hazardous industrial and process applications.

Key features

  • Hydrogen Pressure Transducer uses Ashcroft’s proven CVD thin film technology
  • +/-0.25%, +/- 0.50% or +/-1.0% of span accuracy available
  • Standard ranges from vacuum to 20,000 psi and 0 to 500 psia (custom ranges available)
  • Rugged 316 stainless steel Housing
  • Diaphragm available in 17-4 PH, 316L stainless steel or A286
  • E2X- Flameproof, intrinsically safe and non-incendive approval for explosion-proof/hazardous applications.
  • E2F- Flameproof approval for explosion-proof/hazardous applications.
  • FM, ATEX and IECEx approvals
  • 4-20mA or multiple Voltage outputs available
  • External magnetic offset and span adjustment
  • CE approved
  • RoHS compliant
  • Wide selection of process connections available
  • Customizable configurations
  • External magnetic offset & span adjustment
  • Barometric pressure ranges available (standard & custom ranges)
  • Thick sensing diaphragm using proven CVD technology:
    • 316L SS ranges to 5000 psi/350 bar
    • A286 ranges to 20,000 psi/1400 bar

Specifications

  • Accuracy: ±0.25%, ±0.5%, ±1.0% of span Terminal Point Method includes: hysteresis, non-repeatability, zero offset and span setting errors
  • Outputs:
    • 0-10 Vdc (3 Wire), 0-5 Vdc (3 Wire), 0.1-10 Vdc (3 Wire), 0.1-5 Vdc (3 Wire), 0.5-4.5 Vdc (3 Wire)
    • 1-11 Vdc (3 Wire), 1-5 Vdc (3 Wire), 1-6 Vdc (3 Wire), 20-4 mA (2 Wire), 4-20 mA (2 Wire)
  • Process Connection:
    • 1/4 NPT Male, 1/8 NPT Male, ½ NPT Female, ½ NPT Male, ½-14 NPT Female, ¼ NPT Female
    • ¼˝ VCR gland with 9⁄16-18 Female Swivel Nut, ¼˝ VCR gland with 9⁄16-18 Male Swivel Nut, ¼-18 NPT Female
    • 1⁄8 -27 NPT Female, 7⁄16-20 UNF-2B SAE J1926, 7⁄16-20 UNJF-2A SAE Male (SAE J1926 O-Ring Boss seal)
    • 7⁄16-20 UNJF-3A 37° Flare (SAE AS4395), 9⁄16-18 UNF-2B Female, G1/4 A-MALE (stud end DIN 3852-E G¼)
    • G½ B Male (EN837-1), G¼ B-Male (EN837-1), Sanitary Seal 1.5˝ Tri-Clamp®, Sanitary Seal 2˝ Tri-Clamp®
  • Pressure Ranges
    • Vacuum to 20,000 psig, 0 to 500 psi absolute
  • Shock & Vibration Resistance
    • 10g RMS 20-20,000Hz Vibration
    • 80g, 6ms Haversine Shock

Materials

  • For wetted components:
    • Diaphragm: 17-4PH Stainless steel, 316L Stainless steel, 316L Stainless steel liquid isolated, A286 Process Connection: 316L Stainless Steel
  • For non-wetted components:
    • Housing: 316L Stainless steel

Application areas

  • Hydrogen filling stations
  • Hydrogen compressors
  • Hydrogen storage tanks
  • Reactor vessels
  • Fuel cells for vehicles

Contact us

  • Ashcroft is a trusted source for pressure, temperature, and test instruments around the world. Interested? Please contact the vendor by filling in the contact request form.
Brand Ashcroft
Ingress Protection Rating IP66, IP67, IP69K
Compliant with ATEX, CE, FM, IECEx, UKCA
Max Ambient Temperature (in °C) 125
Min Ambient Temperature (in °C) -40
Ashcroft You shouldn't have to be an expert in pressure and temperature instrumentation to get the right components for your hydrogen applications. You need a partner with expertise in the hydrogen industry who can help you meet instrument quality and safety requirements. Ashcroft has decades of experience partnering with customers and offering solutions for their hydrogen applications including pressure sensors (transducers and transmitters), pressure gauges, pressure switches, diaphragm seals and temperature sensors. Let us help you navigate the expanding hydrogen market and its demands.
99% of all inquiries get answered within 5 days. Your inquiry will be sent immediately to the right person within the vendor organisation.

By ticking the checkbox, you consent to the collection and storage of the data you have provided for the purpose of contacting and answering your request in accordance with our Privacy Policy. You can revoke your consent at any time by sending an email to bye-bye@hyfindr.com.

By ticking the checkbox, you consent to the collection and storage of the data you have provided for the purpose of contacting and answering your request in accordance with our Privacy Policy. You can revoke your consent at any time by sending an email to bye-bye@hyfindr.com.

Latest products

Browse the Hyfindr Digital Ecosystem

Forum icon
Hyfindr
Tech Videos
Assignment icon
Hyfindr
Tech Knowledge
Thumb up icon
Hyfindr
Tech Advisory
Group icon
Hyfindr
Tech Community