Multi-channel hydrogen gas detection system - MX 62

Teledyne Gas & Flame Detection

  • Up to 64 secured channels for direct or network wiring
  • Direct network and loop connection
  • Redundancy from measurement to alarm relays
  • Functions AND, OR, MIN, MAX, Voting available
  • Reliable and Secure Installation
  • Modular hydrogen gas detection system
  • Flexibility allows better integration with your system

Add to compare

Multi-channel hydrogen gas detection system - MX 62

  • MX62 is a stationary control system to be used in combination with a variety of detectors for continuous detection of combustible gases, toxic gases and oxygen.
  • The hydrogen gas detection controller is a modular and flexible controller that is easy to install and reduces operational costs.
  • It has high reliability and flexibility.
  • The flexibility refers to all areas, as there are free programmability, installation of relay and analog output modules and the optional installation in wall-mounted housings, 19 inch racks or control panels.
  • The modular components allow extension for up to 64 channels, 128 relays, 64 analog outputs and the optional use of an LCD module with data logger or profibus module, making the gas detection system suitable for all applications.
  • The complete system and all required modifications can be set by the software 'ConfigPro'.
  • The ConfigPro.exe software configures the MX 62 through a secure, password protected interface. This software is detailed separately.
  • The system consists of a controller module plus various other modules linked by digital busses.
  • The basic configuration is as follows:
    • Analog input module (AEM)
    • Controller module (CM)
    • LED module
    • LCD or logo module
  • The AEM converts the 4-20 mA signal of the detectors into digital bus signals to be transmitted to the CM.
  • In the CM the signals are evaluated and separately indicated for each channel according to the respective pre-settings.
  • One AEM and one LED module are designed for eight channels each.
  • The CM can directly be employed for 64 channels on different input and output modules.
  • In addition the following modules can be integrated into the system as required:
    • Basic relay module (RBM)
    • Extension relay module (REM)
    • Analog output module (AAM)
    • Loop module (LOOPM)
    • LCD data logger module
    • Profibus module (PBM)
    • Analog input extension module (AEAM)
    • LCD copy module
    • MIMIC module
  • For a more detailed description of all the modules and the hydrogen gas detection system please see here.
  • The MX 62 system meets the requirements of ATEX 100 A and offers the high level of security required by SK2 and SIL3 rated systems.
  • The structure of the multi-channel hydrogen gas detection system has been developed to provide redundancy.

Key features

  • Monitoring system for gas and flame detection.
  • Up to 64 secured channels for direct or network wiring
  • Direct network and loop connection
  • Redundancy from measurement to alarm relays
  • Functions AND, OR, MIN, MAX, Voting available
  • Cost Effective and Secure Installation
  • Structured programming
  • Hydrogen gas detection system saves Space and Optimizes Cost
  • Innovative design meets the new safety requirements
  • Modularity allows a personalized operation and custom wiring
  • Flexibility allows better integration with your system
  • High reliability ensures minimum maintenance
  • Programmable outputs reduce relay requirements
  • SIL3 and SIL2 according to EN50402:2006 and IEC61508:2011

Application areas

  • Hydrogen refueling stations
  • Hydrogen Power plants
  • Fuel Cell Test Stations

Contact us

  • With more than 100 years of experience, Teledyne Gas And Flame Detection is a global leader in flame and gas detection systems. Interested? Please contact the vendor by filling in the contact form or RFQ form.
Brand Teledyne Gas and Flame Detection
Min Current (in A) 0.004
Max Input Voltage (in V) 24
Max Current (in A) 0.02
Manufacturing Readiness (MRL) 0
Technology Readiness (TRL) 0
Compliant with ATEX, CE, EAC, SIL 2, SIL 3
Teledyne Gas & Flame Detection

Our dedication to safety, backed by more than 100 years of gas detection experience, has made us a global leader in flame and gas detection systems. Gas and flame detection is required when hydrogen is produced, stored, transported and used. Different equipment and systems are recommended for various applications, but safety is a priority throughout the whole length of the hydrogen value chain. Always sensing safety, everywhere you look, Teledyne’s global portfolio of products and safety solutions are unquestionably first in class.

99% of all inquiries get answered within 5 days. Your inquiry will be sent immediately to the right person within the vendor organisation.

Latest products

Browse the Hyfindr Digital Ecosystem

Suppliers icon
Hyfindr
B2B Suppliers
Forum icon
Hyfindr
Tech Videos
Assignment icon
Hyfindr
Tech Knowledge
Thumb up icon
Hyfindr
Tech Advisory
Group icon
Hyfindr
Tech Community