Electrolyzer Test Station

  • All Inclusive Single Chassis Design
  • Precision and Selective Power Supply
  • Flexible specification by custom made
  • Single, Short Stack, Hight Power Stack Test Station(~500kW)
  • Fully Automatic control Hardware & Software
  • High Technology and Low-Cost Manufacturing
  • Generated Gas Flow(H2, O2) Measurement
  • Crossover Gas Concentration Monitoring
  • Gas Dryer
  • N2 Purge System
  • Temperature Control & Monitoring
  • Line Heater

Compare
Bookmark Add to list

Electrolyzer Test Station (PEM/AEM/Alkaline/SOEC/Others)

  • LabVIEW-Based Ideal Operating Software
  • Ideally harmonized with the hardware system
  • Simple and visual, click-based intuitive operation
  • User-configurable alarms for all operating conditions
  • Runs automatically based on user-written protocols
  • Software customized to match the connected hardware 

Key Features

  1. Power Supply Module
    • Max 1kW, 5kW, 10kW, 50kW, 100kW, 300kW, 500kW
    • LAN Communication
  2. Floor Standing & Housing Cabinet
    • Dimension Custome Size
    • Including All Required Hardware & Connection Fittings
    • Independent Cell Test Door Room
    • Driving warning light
  3. Mass Flow Meter
    • Anode : O2 Generation Range
    • Cathode: H2 Genration Range
    • Accuracy ±0.8% of Reading or ± 0.2% of F.S
  4. Gas Concentration Sensor
    • 0-5% H2 in O2 gas line
    • 0-5% O2 in H2 gas line
    • 3 decimal reading point(0.000%)
  5. Line Heater
    • Flexible Heater, Direct Gas Temp Control
  6. N2 Purge
    • Auto Purge Gas Flow for Anode & Cathode
    • Valve Operation 
  7. PEM/AEM/ALK Water Circulation System
    • Temperature control, max 95℃
    • SUS 316L Tank Electropolishing
    • Circulation Pump, RPM Control Driver
    • Flow Control Range LPM
    • Water Purity Control 0.10-1.00 µS/cm(Ion-Filtering)
    • Sight Glass, Auto Level & Alarm Sensor, Drain port
  8. Automatic Water Fill
    • DI Water Filling to PEM Water Tank
    • High Pressure Pump, 10bar, On/Off Check Valve
  9. Auto Back Pressure Control & Monitoring
    • Max 10bar Sensor & Control
    • Flow Proportional Control Valve & Bypass mode
    • Max Operating Temp 125℃
  10. Water Trap
    • Gas Cooling  Device  & Water Condensation Trap
    • Dryer Chamber & Drierite

Optional Item

  • AC-Impedance Measurement with Power Supply Combination
    • EIS 10mHz-10KHz, HFR with I-V Test
    • Full Current Range Test

Contact us

  • Interested? Please contact Scitech by filling in the RFQ or Inquiry form.

Latest products