Hydrogen High Flow Solenoid Valve with Integrated Check Valve - HyValve Mosaic - H35 - H70

Eugen Seitz AG

  • Flanged valve connection for H2 applications, e.g. H2 refueling
  • Hydrogen high flow solenoid valve with integrated high-flow check valve
  • Automatic cascading eliminating the need for many meters of stainless steel MP piping and up to several hundred bolting points
  • Valve junction: Complete flexibility in the refueling experience

Add to compare

Hydrogen high flow solenoid valve with integrated check valve - HyValve Mosaic - H35 - H70

  • Design your own HyValve Mosaic:
    • with 2 to 40 solenoid valves in any matrix
    • whether 500 bar or 1000 bar
    • individually removable valves
    • maintenance can be carried out in-situ
    • integrated check valve
    • 2/2-way solenoid valve, NC
  • Pressure range: 10 bar to 1000 bar (145 psi to 14500 psi)
  • Single test valves are available
  • Hydrogen solenoid shut-off valve, piloted with own fluid
  • Every valve tested at 100% with hydrogen gas mixture
  • All wetted materials fully hydrogen compatible, no hydrogen embrittlement
  • High-performance dynamic seals for tightness and long service life

Key features

  • Different MP tubing sizes: 9/16', 3/4', 1'
  • Piping connections to the baseplate of HyValve Mosaic: MP Cone & Thread
  • Kv m3/h | Cv US-gal/min depend on the orifice of the HyValve Mosaic mounted valve
  • Pressure range up to 1000 bar
  • Lifetime 500000 cycles
  • Rated voltage 24V AC/DC or 230V AC
  • Rated power 16W
  • Operating time: 100% continuous duty
  • Relative humidity: max. 95% (non-condensing)
  • IP-Code 65/67 according to EN 60529

Benefits

  • Small: most compact system design with best accessibility
  • Reduced C&T connections: minimized leakage points, e.g. 3x3 -> 6 connection points
  • Maintenance at site: individually removable valves only 5 to 8min needed to exchange HyValve with integrated check valve
  • Easy functionality and leakage via system control
  • Eliminated pneumatic air  (no humid air = no freezing issues)
  • Ease of mind during refueling

Solenoid coil 2F86: Approvals

  • EPS 18 ATEX 1098 X
  • IECEx EPS 18.0055 X
  • NEPSI GYJ 18.1429 X
  • II 2G Ex mb IIC 150°C(T3) …(T4*) Gb (* T4 up to +65°C ambient)

Application areas

  • Suited for all high-pressure hydrogen applications
  • Hydrogen Refueling Stations (HRS): Cascade storage valve/priority panels and dispensers
  • Trailer and mobile refueling
  • Medium pressure fluid handling systems
  • Test applications

Project cases

  • Hydrogen Refueling Stations (HRS), HyValve Mosaic is used for managing hydrogen gas flow in and between storage banks (cascade), cryo-pump, compressor and dispenser
  • The highest-capacity and fastest-flow refueling stations in the world rely on HyValve performance
  • HyValve Mosaic are actively operating in refueling stations in California, USA
  • HyValve Mosaic are also used as shut-off valves upstream of hydrogen pressure regulators, to enable the downstream pressure regulator to remain gas-tight

Contact us

  • With top-notch know-how and access to quality solenoid valve technology, Eugen Seitz is a high-pressure technology leader. Interested? Contact the vendor by filing the contact vendor form or RFQ form.
Brand Eugen Seitz
Max Pressure (in bar) 1000
Nom Power (in kW) 0.016
Nom Output Voltage (in V) 230
Ingress Protection Rating IP65, IP67
Manufacturing Readiness (MRL) 0
Technology Readiness (TRL) 0
Max Ambient Humidity (in % r.H.) 95
99% of all inquiries get answered within 5 days. Your inquiry will be sent immediately to the right person within the vendor organisation.

By ticking the checkbox, you consent to the collection and storage of the data you have provided for the purpose of contacting and answering your request in accordance with our Privacy Policy. You can revoke your consent at any time by sending an email to bye-bye@hyfindr.com.

By ticking the checkbox, you consent to the collection and storage of the data you have provided for the purpose of contacting and answering your request in accordance with our Privacy Policy. You can revoke your consent at any time by sending an email to bye-bye@hyfindr.com.

Latest products

Browse the Hyfindr Digital Ecosystem

Forum icon
Hyfindr
Tech Videos
Assignment icon
Hyfindr
Tech Knowledge
Thumb up icon
Hyfindr
Tech Advisory
Group icon
Hyfindr
Tech Community